The greeting option returns, but it is now sent as an automatic reply to
incoming messages only when "Route incoming messages to Assist" is disabled,
so senders get an acknowledgement instead of silence. When Assist handles
messages the greeting is not used. Blank disables it.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Drops the CONF_GREETING option, the first-contact greeting logic and its
RuntimeData state, and all related strings/translations/README text. Any
greeting value left in an existing entry's options is simply ignored.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
- messages_sent now increments when a message is queued (async_send_message),
not only when a delivery proof returns. LXMessage's delivery callback only
fires on a returned proof (LXMessage.py ~566), which many peers/methods never
send, so the "Messages sent" sensor was stuck at 0 for messages that were
actually delivered. The delivery callback now only emits the event.
- Implement the previously-inert "greeting" option: send it automatically the
first time each sender contacts HA (tracked per sender in RuntimeData).
- Clarify the notify entity (rename to "Send message" / "Отправить сообщение")
and document greeting + notify in strings/translations/README.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The interface-status poll was registered as a plain lambda, so
async_track_time_interval ran it in an executor thread, where its
_push_state()->async_dispatcher_send() call tripped HA's thread-safety guard.
Make refresh_interface_status a @callback (it only reads fast in-memory
interface attributes) and pass it to async_track_time_interval directly.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Root cause of setup failure: Reticulum.__init__ calls signal.signal() with no
main-thread guard, but we (correctly) initialise off the event loop in an
executor thread, where signal.signal() raises ValueError. It failed after
setting the __instance singleton, which both broke setup and caused the
"Attempt to reinitialise Reticulum" error on every retry.
- Temporarily neutralise signal.signal during RNS init so init completes in the
executor, and so RNS does not hijack HA's SIGINT/SIGTERM (needed for clean
shutdown under Kubernetes).
- Unregister RNS's and LXMF's atexit exit handlers, which otherwise persist
state with blocking file I/O on the event-loop thread and detach HA's
stdout/stderr at interpreter exit (the loop-blocking warnings seen in logs).
- Persist RNS/LXMF state ourselves off-loop on the homeassistant_stop event.
Documents the remaining non-daemon RNS worker threads as a known shutdown note.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Custom integration connecting Home Assistant to a Reticulum network over a
TCPClientInterface and exchanging LXMF messages, with an Assist conversation
bridge, notify entity, sensors (incl. interface telemetry), buttons, services,
bus events and device triggers.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>